Author Topic: New float style wet bulbs  (Read 329 times)

Offline TILLAMOOK

  • Newbie
  • *
  • Posts: 14
    • View Profile
New float style wet bulbs
« on: May 30, 2017, 08:05:37 AM »
New float style wet bulbs: is a flow meter still needed?
  • No, not if they are working correctly.  Although there may be a benefit of a visual flow indicator and an individual shut off per wet bulb
« Last Edit: May 30, 2017, 08:09:00 AM by DebbieBoyd »

Offline DrykilnsMan

  • Newbie
  • *
  • Posts: 2
    • View Profile
Re: New float style wet bulbs
« Reply #1 on: July 27, 2017, 08:08:26 AM »
We started upgrading to these, and have found that if you don't have clean water (i.e.. softened ) crud builds up quite rapidly on the sock and it begins to read incorrectly, which greatly affects the wet bulb control.

 